| Descriere produs: | DTX 1800 Fluke
Trei Mari facilitati diferentiaza analizorul profesional DTX de la Fluke networks fata de altele de pe piata:
1. Are precizie similara cu a unui aparat de laborator si durabilitatea unui aparat de teren - aparat de incredere
2. Certifica in numai 9 secunde un link de CAT6 fata de 36 secunde un tester similar - testati mai mult in acelasi timp.
3. Numai DTX are tehnologie "Time Domain CrossTalk" singura ce identifica locurilor cu defect de NEXT - salvam timp&bani
DTX - Facilitati Client - Avantaje
Reduce timpul de test, crescand profitabilitatea
Garantie asigurata, confidentialitate maxima.
Identificare probleme de performanta sau instalare.
Un singur aparat poate testa toate mediile.
O zi intreaga de lucru fara baterii aditionale.
Trecere de la un mediu la altul in doar 1 secunda.
Rapoarte profesionale, analiza statistica a datelor.
Depaseste toate cerintele de acuratete.
Usor de folosit Cerinte minime de pregatire a personalului.
Teste pe cupru, fibra, cablu coaxial si retele active.
Testare cupru si fibra intr-un singur aparat.
LinkWare
Aprobat de peste 30 de producatori de Cat6.
Autonomie a bateriei de pana la 12 ore
Mai multe rezultate de PASS
Cat 5/5e/6/D/E/F (CAT 7) cu modul optional / fibra optica cu modul optional
900 MHz bandwidth
|
Standards
|
TIA Category 3 and 5e per TIA/EIA-568B,
TIA Category 5 (1000BASE-T) per TIA TSB-95,
TIA Category 6 per TIA/EIA-568B.2-1 (Addendum #1 to TIA/EIA-568B.2),
ISO/IEC 11801 Class C, D, E, F, EN 50173 Class C, D, E, F (Category 7)
ANSI TP-PMD IEEE 802.3 10BASE-T,
100BASE-TX,1000BASE-T, IEEE 802.5 (STP,
IBM Type 1, 150 Ohm) Token Ring,
4 Mbps i 16 Mbps
|
|
Speed of autotest
|
10s (full 2-way autotest of category 6 twisted-pair links)
|
|
Suported tests
|
wiremap,
length,
propagation delay,
delay skew,
DC Loop Resistance,
Insertion Loss,
Return Loss (RL),
RL @ Remote NEXT,
NEXT @ Remote,
Attenuation-to-crosstalk Ratio (ACR),
ACR @ Remote,
ELFEXT,
ELFEXT @ Remote,
Power Sum ELFEXT,
PSELFEXT @ Remote,
Power Sum NEXT,
PSNEXT @ Remote Power Sum ACR,
PSACR @ Remote
|
|
Tone generator
|
build-in,
440 Hz ÷ 831 Hz
|
|
Bandwidth
|
900 MHz
|
|
Accuracy level
|
IV
|
|
Display
|
3,7",
resolution 240x320,
passive color with backlight
|
|
Working in active network
|
yes (optional DTX-NSM adaptor)
|
|
Graphical results memory
|
250 records
|
|
External memory
|
16 MB
|
|
USB connector
|
yes
|
|
RS-232 connector
|
yes
|
|
"Channel type" adapters cat.6
|
yes
|
|
Additional features
|
build-in VFL,
remote autotest
|
|
Dimensions
|
216x112x60 mm
|
|
Weight
|
1,1 kg
|
|
Operating temperature
|
0°C ÷ 45°C
|
|
Operating humidity
|
0% ÷ 70%,
non-condensing
|
|
Vibration
|
2g,
5 Hz ÷ 500 Hz
|
|
Shock
|
1m drop test without module
|
|
Altitude
|
4000 m
|
|
Power
|
Li-Ion power cell,
7,4 V,
4000 mAh
|
|
Calibration validity
|
1 year
|
|
Supported languages
|
English,
French,
German,
Spanish,
Portuguese,
Italian
|
|
Manufacturer
|
|
DC Loop Resistance Test |
|
Parameter
|
twisted pair cabling
|
|
Range
|
0 Ohm ÷ 53 Ohm
|
|
Resolution
|
0,1 Ohm
|
|
Accuracy
|
± (1 Ohm + 1%)
|
Delay Skew |
|
Parameter
|
twisted pair cabling
|
|
Range
|
0 ns ÷ 100 ns
|
|
Resolution
|
1ns
|
|
Accuracy
|
± 10 ns
|
Length for twisted pair cabling |
|
Range
|
800m (single-ended test),
150m (dual-ended test)
|
|
Resolution
|
0,1 m
|
|
Accuracy
|
± (1m + 4%)
|
|